Case Name: wine
Explanation: Test the product: winePeriod: From 18 May 2005 to 28 June 2005Journey: From South Africa to USA Three data loggers were placed in the different positions in the container  Position of Data A Loggers in the container1.This logger was placed outside the Envirotuff liner and stuck onto the inside of the roof. 2.The temperatures experienced are almost unbelievable, with the max. temp of 73.1 degrees celcius on 21 June 2005. See next slide. 3.The daily spikes in temperature is the major problem for wine, with variances of up to 50 degrees in a 12 hour period were experienced. 4.The outside temperature was obviously not as high, but the container walls and roof heat up so much that inside the container, temperatures increase dramatically   Position o...
Case Name: Beer
Explanation: Product: Tiger BeerPeriod: 28 Oct, 2005 - 13 Dec, 2005Shipment: From Singapore to Neimenggu, ChinaProblem: Low-temperature impact on beer qualityThere are two container installed to test the data logger.      Test Report:Container 1:In ETL the temperature is as below: The Highest is 43 degrees, The Lowest is -1 degrees.In aircap the temperature is as below: The Highest is 72 degrees, The Lowest is -17 degrees.Container 2:In ETL the temperature is as below: The Highest is 36 degrees, The Lowest is -4 degrees.In aircap the temperature is as below: The Highest is 69 degrees, The Lowest is -20 degrees.
Case Name: Beverage
Explanation: Company :The Coca Cola Export Corporation, Calubang, PhilippinesDate & Time :August 23rd, 2005 approx. 1830 hrs to August 27th, 2005 approx. 0806 hrsTrial Specification :A 20ft container equipped with 2 Dickson Tp120 data loggersData Logger 1 – on the top pointof the container outside ETLData Logger 2 – on the top point of the ETL Trial Results:Data Logger 1 (Outside Liner)Data Logger 2 (Inside Liner) Finding:Enviro-tuff AV Liner has significantly proven that it is capable of:Stabilizing the environment and temperature inside the liner below 35℃ (MAX = 33.3℃) during the 5 days shipment period at the highest point of the container without extreme temperature spikes Maintaining the quality of goods Minimizing the risk of defects/ rejects
Explanation: Industry : Cocoa IndustryProducts : Cocoa PowderShipment : Malaysia to RussiaPeriod : 10 Sep 04 – 3 Nov 04Problem : Caking       Findings:Air gap temperature for container install with ETL liner changed from 0℃ to 65℃ the lowest temperature is 1.12℃, the average is 13.67℃,Temperature for container insulated with ETL changed from 4℃ to 40℃. ETL took a good protection for goods.
Case Name: Cocoa Bean
Explanation: Company:Olam International LtdProduct : Cocoa BeanPeriod : 12 July 05 - 29 August 05Shipment : Nigeria to MalaysiaProblem : Moisture Sensitive Mouldy  Placement of Data Logger Container without ETL LinerPlacement of Data Logger Container with ETL Liner
Case Name: Chocolate-1
Explanation: Companies: Cadbury Schweppes, JMP HoldingsDates: October 22 – 24, 2003Melting temp : 25℃ – 28 ℃Journey: Queensland, Archerfield to TownsvilleAttendees: Nicholas Daniel, John Beever, Simon O’Donnell CONTAINER LAYOUT  The 6 data loggers used for this trial were all placed in the centre of a pallet .3 of the pallets were protected by the Envirotuff Pallet Cover whilst ,the other 3 were transported with no thermal protection.  These pallets were placed in a sealed (but not airtight) 20’ container that was transported by rail from Archerfield to Townsville (both Queensland).  Data recordings were taken over a 48 hour period where the unofficial temperature outside hovered around 30℃ elsius during the day.  The west side of the container was most exp...
Case Name: Chocolate-2
Explanation: Products : ChocolateMelting temp : 25℃ – 28℃Dates: February 5-9, 2004Journey:Queensland, Archerfield to CairnsCompanies: Cadbury Schweppes, JMP HoldingsAttendees: Nicholas Daniel and John Beever Logger and Pallet Cover Positioning The west side of the container was most exposed to the sun.   The 8 data loggers used for this trial were all placed in the centre of a pallet. 4 of the pallets were protected by the Envirotuff Pallet Cover whilst the other 4 were transported with no thermal protection.  These pallets were placed in a sealed (but not airtight) 20’ container that was transported by rail from Archerfield to Cairns (both Queensland).  Data recordings were taken over a 5 day period where the unofficial temperature outside hovered around an...
Explanation: Products : Lauric Acid, Stearic Acid Period : 17 March 04 – 23 March 04 Melting temp : 33℃ – 43℃ Container A – No InsulationTwo material, Lauric acid and Stearic acid is lifted up by pallets and placed near to container roof.One temperature data logger in placed on the material to monitor the container temperature and RH%.Container is then close and leave under the sunlight for 7 days. Container B – Insulated with paper boardTwo material, Lauric acid and Stearic acid is lifted up by pallets and placed near to container roof.One temperature data logger in placed on the material to monitor the container temperature and RH%Container is then close and leave under the sunlight for 7 days.  Container C – Insulated with StyrofoamTwo material, Lauric acid and Stearic acid is li...
Explanation: Products : Lauric Acid WPeriod : 4 Jun 04 – 19 July 04 Shipment : Malaysia to USAMelting temp: 43 ℃ Data Logger Position:One 20ft container installed with ETL liner, 20 pallets of lauric acid were shipped with this liner from Port Klang to USA.Two pieces of data logger were installed, one inside the liner area and one in the air gap, to monitor the container temperature and humidity for the whole journey.    Trial Result:Maximum temperature recorded for air gap is 54.7℃, minimum is 13.4℃.Maximum temperature for insulated area is 38.1 ℃, minimum is 17.9℃. MATERIAL EVALUATION AFTER ARRIVED USA:No melting and caking problem when material arrived USA.