Test the product: wine

Period: From 18 May 2005 to 28 June 2005

Journey: From South Africa to USA

 

Three data loggers were placed in the different positions in the container

wine

 

 

Position of Data A Loggers in the container

1.This logger was placed outside the Envirotuff liner and stuck onto the inside of the roof.

 

2.The temperatures experienced are almost unbelievable, with the max. temp of 73.1 degrees celcius on 21 June 2005. See next slide.

 

3.The daily spikes in temperature is the major problem for wine, with variances of up to 50 degrees in a 12 hour period were experienced.

 

4.The outside temperature was obviously not as high, but the container walls and roof heat up so much that inside the container, temperatures increase dramatically

 

wine

 

 

Position of Data B Loggers in the container

1.This data logger was inside the Envirotuff Liner, near to the top of the pallets of wine.

 

2.On the graph in the next slide, it shows the temperatures experienced by the data logger. You can clearly see how the Envirotuff Liner protected the wine from temperature variances, as apposed to the graph on slide 6.

 

wine

 

 

Position of Data C Loggers in the container

1.This data logger was inside the Envirotuff Liner, nearer the bottom of the pallets of wine.

 

2.The max. temp reached was 29.4 degrees celcius on the 28 June 2005, the day the container was opened.

 

wine

 

 

Conclusion:

The testing done conclusively proves that the Envirotuff Liner protects the containers contents from temperature fluctuations.

Data logger No.1 – Outside liner - Max. temp = 73.1℃, Min. temp = 10.7℃ - A difference of 62.4℃.

Data logger No.2 – Inside liner (top) - Max. temp = 31.7℃, Min. temp = 16.7℃ - A difference of 15℃.

Data logger No.3 – Inside liner (lower) - Max. temp = 29.4℃, Min. temp = 15.7℃ - A difference of 13.7℃.

 

wine

 

Prev:NoneNext:Beer
Case / Case
2016 - 05 - 30
Test the product: winePeriod: From 18 May 2005 to 28 June 2005Journey: From South Africa to USA Three data loggers were placed in the different positions in the container  Position of ...
2016 - 05 - 30
Product: Tiger BeerPeriod: 28 Oct, 2005 - 13 Dec, 2005Shipment: From Singapore to Neimenggu, ChinaProblem: Low-temperature impact on beer qualityThere are two container installed to test the data logg...
2016 - 05 - 30
Company :The Coca Cola Export Corporation, Calubang, PhilippinesDate & Time :August 23rd, 2005 approx. 1830 hrs to August 27th, 2005 approx. 0806 hrsTrial Specification :A ...
Close Window】【Print
Copyright © 2005 - 2013 Shanghai ENSI industrial Co.,Ltd 
犀牛云提供企业云服务
Address:Shanghai Jinzhong Road No. 658 Building No. 10 room 508
Tel: 86-21-51699397
传真:+86 0755-2788 8009
邮编:330520